Optimized and Application-Tested for the Analysis of Hydrophilic Organic Acids
The Acclaim? OA column offers unparalleled separations of hydrophilic aliphatic and aromatic organic acids using 100% aqueous phase and at low pH, using UV detection. The Acclaim OA column line features a patented polar-embedded stationary phase that is optimized and use-tested for hydroxyl aliphatic organic acid separations.
Use-tested to guarantee consistent hydrophilic organic acid separations
Compatible with 100% aqueous phases, optimum for hydrophilic organic acid retention
Hydrolytic stability at low-pH conditions, optimum for reversed-phase retention of organic acids
Ideal selectivity for separating a wide spectrum of organic acids
Excellent peak shapes for organic acids
The Acclaim OA organic acid columns can be operated at low pH and at 100% aqueous phases, conditions ideal for retaining and separating a wide spectrum of organic acids. Acclaim OA columns undergo extensive testing to ensure column-to-column reproducibility, and are shipped with certificates of analysis detailing these tests. The Acclaim OA columns are packed in metal-free PEEK? column bodies, to eliminate unwanted interaction between the analytes and the column body.
Acclaim OA is the recommended column for determining small hydrophilic organic acids, C1 to C7 aliphatic acids, and hydrophilic aromatic acid and is also valuable for the analysis and quality assurance of food and beverage products, pharmaceutical preparations, plating baths, and manufacturing chemicals and chemical intermediates.
Acclaim OA Column Applications
Applications include analysis of foods, beverages, pharmaceuticals, chemical intermediates and environmental samples. For example: aliphatic organic acids in foods (juice, wine, drinks), organic acids in drug preparations, acrylic acid and its oligomers, hydroxybenzoic acids, hydroxyphenylacetic acids, arylacetic acids, benzenpolycarboxylic acids and selected amino acids.
技術(shù)參數(shù):
Acclaim OA Silica-Based Columns for the Separation of Organic Acids Specifications
Particle size
3?m and 5 ?m
Particle shape
Spherical
Particle size distribution (40/90)
<1.3
Total carbon content
17%
Surface coverage
2.7 mmol/m2
End-capped
Yes
Metal impurity (ppm), Na, Fe, Al
<10.0 ppm Total Metal <3.0 ppm Individual Metal
Pore volume
1.0 mL/g
Average pore diameter
120 ?
Surface area
300 m2/g
pH range
2–8
Temperature
<60 °C
Starting material
Ultrapure silica
訂購信息:
Analytical Columns
Acclaim OA, 3?m Analytical, (3.0 x 150mm)
070086
Acclaim OA, 3?m Analytical, (2.1 x 150mm)
070087
Acclaim OA, 5 ?m Analytical (4 x 250 mm)
062902
Acclaim OA, 5 ?m Analytical (4 x 150 mm)
062903
Guard Columns
Acclaim OA, 5 ?m Guard Cartridge (4.6 x 10 mm), 2 ea (use V-2 Holder)